Notifications
You must be signed in to change notification settings - Fork 5.3k
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Load cell gram scale #6729
Open
garethky
wants to merge
3
commits into
Klipper3d:master
Choose a base branch
from
garethky:pr-load-cell-gram-scale
base: master
Could not load branches
Branch not found: {{ refName }}
Loading
Could not load tags
Nothing to show
Loading
Are you sure you want to change the base?
Some commits from the old base branch may be removed from the timeline,
and old review comments may become outdated.
+701
−2
Open
Load cell gram scale #6729
Changes from all commits
Commits
File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,102 @@ | ||
# Load Cells | ||
|
||
This document describes Klipper's support for load cells. Basic load cell | ||
functionality can be used to read force data and to weigh things like filament. | ||
A calibrated force sensor is an important part of a load cell based probe. | ||
|
||
## Related Documentation | ||
|
||
* [load_cell Config Reference](Config_Reference.md#load_cell) | ||
* [load_cell G-Code Commands](G-Codes.md#load_cell) | ||
* [load_cell Status Reference](Status_Reference.md#load_cell) | ||
|
||
## Using `LOAD_CELL_DIAGNOSTIC` | ||
|
||
When you first connect a load cell its good practice to check for issues by | ||
running `LOAD_CELL_DIAGNOSTIC`. This tool collects 10 seconds of data from the | ||
load cell and resport statistics: | ||
|
||
``` | ||
$ LOAD_CELL_DIAGNOSTIC | ||
// Collecting load cell data for 10 seconds... | ||
// Samples Collected: 3211 | ||
// Measured samples per second: 332.0 | ||
// Good samples: 3211, Saturated samples: 0, Unique values: 900 | ||
// Sample range: [4.01% to 4.02%] | ||
// Sample range / sensor capacity: 0.00524% | ||
``` | ||
|
||
Things you can check with this data: | ||
* The configured sample rate of the sensor should be close to the 'Measured | ||
samples per second' value. If it is not you may have a configuration or wiring | ||
issue. | ||
* 'Saturated samples' should be 0. If you have saturated samples it means the | ||
load sell is seeing more force than it can measure. | ||
* 'Unique values' should be a large percentage of the 'Samples | ||
Collected' value. If 'Unique values' is 1 it is very likely a wiring issue. | ||
* Tap or push on the sensor while `LOAD_CELL_DIAGNOSTIC` runs. If | ||
things are working correctly ths should increase the 'Sample range'. | ||
|
||
## Calibrating a Load Cell | ||
|
||
Load cells are calibrated using the `CALIBRATE_LOAD_CELL` command. This is an | ||
interactive calibration utility that walks you though a 3 step process: | ||
1. First use the `TARE` command to establish the zero force value. This is the | ||
`reference_tare_counts` config value. | ||
2. Next you apply a known load or force to the load cell and run the | ||
`CALIBRATE GRAMS=nnn` command. From this the `counts_per_gram` value is | ||
calculated. See [the next section](#applying-a-known-force-or-load) for some | ||
suggestions on how to do this. | ||
3. Finally, use the `ACCEPT` command to save the results. | ||
|
||
You can cancel the calibration process at any time with `ABORT`. | ||
|
||
### Applying a Known Force or Load | ||
|
||
The `CALIBRATE GRAMS=nnn` step can be accomplished in a number of ways. If your | ||
load cell is under a platform like a bed or filament holder it might be easiest | ||
to put a known mass on the platform. E.g. you could use a couple of 1KG filament | ||
spools. | ||
|
||
If your load cell is in the printer's toolhead a different approach is easier. | ||
Put a digital scale on the printers bed and gently lower the toolhead onto the | ||
scale (or raise the bed into the toolhead if your bed moves). You may be able to | ||
do this using the `FORCE_MOVE` command. But more likely you will have to | ||
manually moving the z axis with the motors off until the toolhead presses on the | ||
scale. | ||
|
||
A good calibration force would ideally be a large percentage of the load cell's | ||
rated capacity. E.g. if you have a 5Kg load cell you would ideally calibrate it | ||
with a 5kg mass. This might work well with under-bed sensors that have to | ||
support a lot of weight. For toolhead probes this may not be a load that your | ||
printer bed or toolhead can tolerate without damage. Do try to use at least 1Kg | ||
of force, most printers should tolerate this without issue. | ||
|
||
When calibrating make careful note of the values reported: | ||
``` | ||
$ CALIBRATE GRAMS=555 | ||
// Calibration value: -2.78% (-59803108), Counts/gram: 73039.78739, | ||
Total capacity: +/- 29.14Kg | ||
``` | ||
The `Total capacity` should be close to the rating of the load cell itself. If | ||
it is much larger you could have used a higher gain setting in the sensor or a | ||
more sensitive load cell. This isn't as critical for 32bit and 24bit sensors but | ||
is much more critical for low bit width sensors. | ||
|
||
## Reading Force Data | ||
Force data can be read with a GCode command: | ||
|
||
``` | ||
READ_LOAD_CELL | ||
// 10.6g (1.94%) | ||
``` | ||
|
||
Data is also continuously read and can be consumed from the load_cell printer | ||
object in a macro: | ||
|
||
``` | ||
{% set grams = printer.load_cell.force_g %} | ||
``` | ||
|
||
This provides an average force over the last 1 second, similar to how | ||
temperature sensors work. |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Oops, something went wrong.
Oops, something went wrong.
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
not knowing what a load cell does/means for a 3d printer, could you add a sentence or two describing it's usage/benefits for 3d printers/klipper?
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I made some updates to the documentation including a little bit more exposition at the top and a section about how to read the load cell gram force