The ioBroker.js-controller is the heart of any ioBroker installation. The controller is owning the central configuration of the ioBroker installation and controls and monitors all adapter processes for the current host.
Please check the js-controller compatibility information below which version runs on your Node.js version
- js-controller 4.x works with Node.js 12.x, 14.x and 16.x (incl. up to NPM 8)
- js-controller 3.x works with Node.js 10.x, 12.x, 14.x and probably 16.x (first tests look good, NPM 7 still has some issues, so NPM6 is best)
- js-controller 2.x works with Node.js 8.x, 10.x , 12.x and probably 14.x (untested)
- js-controller 1.x works with Node.js 4.x, 6.x, 8.x and probably 10.x (untested)
Please try to stay current with your Node.js version because the support is limited in Time. As of now (April 2021) all Node.js versions below 12.x are no longer supported by Node.js and considered EOL (End Of Life). To upgrade your Node.js version and ioBroker please follow https://forum.iobroker.net/topic/44566/how-to-node-js-f%C3%BCr-iobroker-richtig-updaten-2021-edition !
- Changelog
- Official website: https://www.iobroker.net
- Forum: https://forum.iobroker.net
- Explanation of the concept: https://github.com/iobroker/iobroker
Example how to install on a Debian based system:
curl -sLf https://iobroker.net/install.sh | bash -
See Linux instructions, Windows instructions and
after that, ioBroker should be running and available in the browser under http://<ip>:8081/
.
- run
iobroker start
to start the ioBroker controller in the background - watch the logfile
iobroker logs --watch
or
- run
node node_modules/iobroker.js-controller/controller.js
in the ioBroker directory to start the ioBroker controller in foreground and watch the log on console.
- run
iobroker start
in the ioBroker directory to start the ioBroker controller as service. The name of the service is "iobroker()" - check the logfile
log/iobroker.log
or
- run
node node_modules/iobroker.js-controller/controller.js
in the ioBroker directory to start the ioBroker controller in foreground and watch the log on console
The main configuration is stored in iobroker-data/iobroker.json
. Normally there is no need to edit this file because the ioBroker CLI commands cancontrol most of the settings.
Feature status: stable
The admin adapter is installed automatically and starts a web-server that hosts the Admin UI. Default port is 8081, so just open http://<iobroker-ip>:8081/
If port 8081 is occupied, you can install a second Admin UI on an alternate port and change the port for the first admin UI. To do so, run iobroker add admin --enabled --port 8090
and go to the http://<iobroker-ip>:8090/
. Of course you can change port 8090 to a different one.
Feature status: stable
The command line interface is described at https://www.iobroker.net/#de/documentation/config/cli.md
Feature status: stable
By default, the hostname for the js-controller instance will be taken from the official hostname of the server ioBroker is running on. The hostname should not be changed after the first start of ioBroker on this host.
If changes are needed there are CLI commands available to update the hostname. Look under https://www.iobroker.net/#de/documentation/config/cli.md for the iobroker host ...
commands
If you need to set a specific hostname before the first start of iobroker you can also edit the iobroker.json file:
{
"system": {
...
"hostname":"local",
...
},
Feature status: stable
By default, the memory management is done by Node.js automatically. A Garbage Collector (GC) will clean up unused objects automatically from time to time.
If needed, especially for low memory situations the memory limit for all adapter processes can be set in iobroker.json
. Only set this if really needed, and you know what you are doing. Leave the value at 0 to not set a special memory limitation.
{
...
"system": {
...
"memoryLimitMB": 0,
...
},
...
}
Feature status: Technology preview since js-controller 3.3.0
The js-controller is able to execute .ts
files, which removes the need of compiling to JavaScript first.
To use this feature, simply define the adapter main file as the required .ts
file.
E.g. in package.json
:
{
"main": "src/main.ts"
}
Note, that the sources need to be presence on every installation and thus need to be included in the npm package. Vice versa, the build folder is no longer required and should not be published to npm any longer.
Technically, the sources are compiled with ESBuild at every startup, hence this feature should not be used on adapters consisting of many sources to prevent noticeably delayed adapter starts.
Feature status: stable
The js-controller is collecting statistics for the host (system.host.hostname.*
), running compact groups (system.host.hostname.compaczgroupX.*
) and for each adapter (system.adapter.adaptername.*
). The data contains memory usage, free memory, number of events and also the event loop lag of the Node.js process.
Feature status: stable since js-controller 3.0.0
Sentry.io is a way for developers to get an overview about errors from their applications. The js-controller uses this method to make sure application crashes are reported to us. With this we can make sure to provide fixes for problems very fast.
Especially with the automatic restart behaviour of ioBroker some crashes happen and no one really realizes them. And so we also do not get bug reports for them. With this method the information are provided to us.
When the js-controller crashes or another Code error happens (and only then!), this error, that also appears in the ioBroker log, is submitted to our own Sentry server hosted in Germany. If you have allowed iobroker GmbH to collect diagnostic data then also your anonymous installation ID (this is just a unique ID without any additional infos about you, email, name or such) is included. This allows Sentry to group errors and show how many unique users are affected by such an error. IP addresses are not stored with the crash report!
All of this helps me to provide an error free smart home system that basically never crashes.
If you want to disable the error reporting you can do this by setting the state "system.host.NAME.plugins.sentry.enabled" to false. You should see a log message stating that sentry was disabled. After disabling the plugin no crashes from your system are reported and so can not be fixed without reporting them by yourself manually!
Feature status: Technology preview since js-controller 3.2.0
The notification system in ioBroker allows setting, detecting and storing notifications per Host and allows to query the details.
Notifications need to be defined in the io-package.json of the adapter in the key notifications
. Notifications are grouped in scopes
and contain categories
of different notification types. Notifications can contain a regex for automatic detection in strings or adapter exception texts.
The definition also contain localized names and descriptions that can be used to display it to the users.
Registered notifications are stored per host and can be requested via messages to the host. They are also stored when the controller stops and loaded on next start.
Additionally, a summary of the stored categories per scope with a number of stored notifications and the last added timestamp is available in the state system.host.hostname.notifications.scopeid
as a JSON.
The js-controller defines in its io-package the system scope together with all details. You can use this as an example and the JSON schema will help you validate your notifications.
{
"notifications": [
{
"scope": "system",
"name": {
"en": "System Notifications",
"de": "System-Benachrichtigungen",
"ru": "Системные уведомления",
"pt": "Notificações do sistema",
"nl": "Systeemmeldingen",
"fr": "Notifications système",
"it": "Notifiche di sistema",
"es": "Notificaciones del sistema",
"pl": "Powiadomienia systemowe",
"zh-cn": "系统通知"
},
"description": {
"en": "These notifications are collected by the ioBroker system and point to issues you should check and fix.",
"de": "Diese Benachrichtigungen werden vom ioBroker-System erfasst und weisen auf Probleme hin, die überprüft und behoben werden sollten.",
"ru": "Эти уведомления собираются системой ioBroker и указывают на проблемы, которые вы должны проверить и исправить.",
"pt": "Essas notificações são coletadas pelo sistema ioBroker e apontam para problemas que você deve verificar e corrigir.",
"nl": "Deze meldingen worden verzameld door het ioBroker-systeem en wijzen op problemen die u moet controleren en oplossen.",
"fr": "Ces notifications sont collectées par le système ioBroker et indiquent des problèmes que vous devez vérifier et résoudre.",
"it": "Queste notifiche vengono raccolte dal sistema ioBroker e indicano problemi che dovresti controllare e correggere.",
"es": "Estas notificaciones son recopiladas por el sistema ioBroker y señalan problemas que debe verificar y solucionar.",
"pl": "Te powiadomienia są zbierane przez system ioBroker i wskazują problemy, które należy sprawdzić i naprawić.",
"zh-cn": "这些通知由ioBroker系统收集,并指出您应检查并修复的问题"
},
"categories": [
{
"category": "memIssues",
"name": {
"en": "Issues with RAM availability",
"de": "Probleme mit der Arbeitsspeicher-Verfügbarkeit",
"ru": "Проблемы с доступностью оперативной памяти",
"pt": "Problemas com disponibilidade de RAM",
"nl": "Problemen met de beschikbaarheid van RAM",
"fr": "Problèmes de disponibilité de la RAM",
"it": "Problemi con la disponibilità della RAM",
"es": "Problemas con la disponibilidad de RAM",
"pl": "Problemy z dostępnością pamięci RAM",
"zh-cn": "RAM可用性问题"
},
"severity": "alert",
"description": {
"en": "Your system is running out of memory. Please check the number of running adapters and processes or if single processes need too many memory.",
"de": "Es steht nicht genug Arbeitsspeicher zur Verfügung. Die Anzahl der laufenden Adapter und Prozesse sollte geprüft werden, oder ob einzelne Prozesse zuviel Speicher benötigen.",
"ru": "В вашей системе не хватает памяти. Пожалуйста, проверьте количество работающих адаптеров и процессов, или если отдельным процессам требуется слишком много памяти.",
"pt": "Seu sistema está ficando sem memória. Verifique o número de adaptadores e processos em execução ou se processos únicos precisam de muita memória.",
"nl": "Uw systeem heeft onvoldoende geheugen. Controleer het aantal actieve adapters en processen of als afzonderlijke processen te veel geheugen nodig hebben.",
"fr": "Votre système manque de mémoire. Veuillez vérifier le nombre d'adaptateurs et de processus en cours d'exécution ou si des processus uniques nécessitent trop de mémoire.",
"it": "Il tuo sistema sta esaurendo la memoria. Controllare il numero di adattatori e processi in esecuzione o se i singoli processi richiedono troppa memoria.",
"es": "Su sistema se está quedando sin memoria. Verifique el número de adaptadores y procesos en ejecución o si los procesos individuales necesitan demasiada memoria.",
"pl": "W Twoim systemie kończy się pamięć. Sprawdź liczbę działających adapterów i procesów lub czy pojedyncze procesy wymagają zbyt dużej ilości pamięci.",
"zh-cn": "您的系统内存不足。请检查正在运行的适配器和进程的数量,或者单个进程是否需要太多内存。"
},
"regex": [
"^Exception-Code: ENOMEM",
"buffer allocation failed"
],
"limit": 10
}
]
}
]
}
Each adapter can define its own "scopes" for own notifications with its own categories which then will be available in the system. Please contact the core development group if you plan to add an own scope so that scope names can be checked to stay unique. The same applies if you see the need to enhance the system scope by additional categories. Let's discuss the requirements that they can also be added officially into upcoming js-controller versions.
A scope and category definition needs to contain all relevant UI texts in the JSON.
An adapter can use the method registerNotification
to register own notifications to the system. To find out if the used controller version supports this feature, check if the method exists (or require at least js-controller 3.2.0).
This method takes the following parameters:
- scope: scope to be addressed
- category: category - to be addressed, if null message will be checked by regex of given scope
- message: message to be stored/checked
When a regex is defined then console.error
output from the adapter is always checked by the regex and notifications are registered automatically when the regex matches!
The host supports the message command getNotifications
to query the stored notifications together with the localized names and descriptions.
The message needs to take the following parameters in the message object:
- scopeFilter - scope of notifications
- categoryFilter - category of notifications
- instanceFilter - instance of notifications
All three are optional and can be a string or null/undefined if omitted.
The host supports the message command clearNotifications
to clear specific notifications after they are handled.
Please only clear notifications that really were handled and displayed to the user especially for "system" scope!
The message needs to take the following parameters in the message object:
- scopeFilter - scope of notifications
- categoryFilter - category of notifications
- instanceFilter - instance of notifications
All three are optional and can be a string or null/undefined if ommited.
Feature status: stable
The js-controller and each adapter has defined its own log level. By default, info
is used. The following log levels can be used:
- silly (most logging)
- debug
- info
- warn
- error (only errors are logged)
The log level for js-controller is configured in iobroker.json in the logs section:
{
...
"log": {
"level": "info",
...
}
...
}
Feature status: stable since js-controller 2.0.0
The log level can be changed dynamically for adapter-instance and host (main controller and compact group controllers) after they have been started. Initially always the configured loglevel is used!
The states system.adapter.xy.logLevel
and system.host.hostname.logLevel
are updated on instance/controller start with the configured log level and can afterwards be used to change the loglevel during runtime. These changes are not persisted, so the next restarts resets the loglevel to the configured one.
The Loglevel change is only effective if there is no loglevel (property "level") defined on the transport configuration.
This possibility allows to debug adapters better and during runtime.
Feature status: stable
The default logging will log file based in the log directory inside the ioBroker directory. The logfile will be stored with a name that contains the date and will be deleted after 7 days. It only contains the logs from the current host.
The logging is configured in the iobroker.json
file and can be changed there:
{
...
"log": {
"level": "info",
"maxDays": 7,
"noStdout": true,
"transport": {
"file1": {
"type": "file",
"enabled": true,
"filename": "log/iobroker",
"fileext": ".log",
"maxsize": null,
"maxFiles": null
},
},
...
}
If you want to pin a special loglevel for the file transport you can add a property "level" with a hard defined loglevel. Then no dynamic control is possible.
Since js-controller 3.0 Logfiles on non-Windows based systems are compressed on rotation, so that the older Files need less space on your storage.
If you do not want to compress the files this behaviour can be deactivated by iobroker.json
:
{
...
"log": {
...
"transport": {
"file1": {
...
"zippedArchive": false,
...
},
},
...
}
Feature status: stable
ioBroker also supports logging to a syslog server. The configuration is also stored in the iobroker.json
configuration file. A section for syslog is pre-created but disabled by default.
{
...
"log": {
...
"transport": {
...
"syslog1": {
"type": "syslog",
"enabled": false,
"host": "localhost",
"host_comment": "The host running syslogd, defaults to localhost.",
"port_comment": "The port on the host that syslog is running on, defaults to syslogd's default port(514/UDP).",
"protocol": "udp4",
"protocol_comment": "The network protocol to log over (e.g. tcp4, udp4, unix, unix-connect, etc).",
"path_comment": "The path to the syslog dgram socket (i.e. /dev/log or /var/run/syslog for OS X).",
"facility_comment": "Syslog facility to use (Default: local0).",
"localhost": "iobroker",
"localhost_comment": "Host to indicate that log messages are coming from (Default: localhost).",
"sysLogType_comment": "The type of the syslog protocol to use (Default: BSD).",
"app_name_comment": "The name of the application (Default: process.title).",
"eol_comment": "The end of line character to be added to the end of the message (Default: Message without modifications)."
}
}
}
...
}
If you want to pin a special loglevel for the file transport you can add a property "level" with a hard defined loglevel. Then no dynamic control is possible.
See the iobroker.json and Admin for more transports and their settings.
If you want to pin a special loglevel for the file transport you can add a property "level" with a hard defined loglevel. Then no dynamic control is possible.
Feature status: stable
ioBroker allows adapters to subscribe to log messages from the whole system. E.g. admin adapter is using this logic
More details for this feature can be found at https://github.com/ioBroker/ioBroker.docs/blob/master/docs/en/dev/logging.md
The full definition for adapter settings can be found at https://github.com/ioBroker/ioBroker/blob/master/doc/SCHEMA.md#adapter
Feature status: stable
ioBroker allows installing multiple adapters on the system. For each adapter the JavaScript code is installed once. For each adapter multiple instances can be created and started with independent configurations.
Feature status: stable
ioBroker supports multiple Adapter modes. These are:
deamon
: The adapter is started and runs all the time. If the process gets killed it will be restarted automatically. This adapter type is mainly used for all situations where communications or actions are done continuously. These adapters also supports a restart schedule where the controller restarts the instances. The adapter needs RAM and some CPU resources also when doing nothing.schedule
: The adapter is started based on a defined schedule (e.g. once per hour, once a day, all 10 minutes ...), then is doing its work and is stopping itself when finished. The adapter is only using RAM and CPU when needed.once
: The adapter ist started only once after it's object got modified. No restarting happens after the adapter stops.subscribe
: The adapter is started when a defined state ID gets set to true, and stopped when set to falsenone
: The adapter is officially not having any process, but could be a webExtension (so iis included by a web instance on the same host or is only running client side and so offering www files)
Feature status: stable
By default, adapters are started by the js-controller as separate Node.js processes. They connect to the state and object DBs to read and write their data and some statistical information.
The js-controller is monitoring the process ids of the started processes and also controls stopping or restarting these processes.
With this approach the whole iobroker system is very robust. A faulty adapter will only affect his own process and the js-controller and the other adapter processes are unaffected.
The downside is that more RAM is required because each Node.js process needs 20-30 MB RAM for the Node.js part of it. With this a 1 GB system is usually limited to run approximately 10 to 15 adapter processes. Aside from using systems with more RAM, distributing adapters onto multiple hosts in a multihost environment is possible.
The compact mode is developed especially for systems with low memory. All adapters configured to run in compact mode will run inside the same process as js-controller.
As a result, each adapter needs 20-30 MB less RAM because it does not need to have its own Node.js process handling. This way, even a system with only 512 MB RAM can run several adapter instances.
The downside is that as soon as one adapter is crashes or generates an unhandled error, the whole js-controller process will be restarted.
To minimize the risk adapter instances are run by default in compact group 1 which means that a second process is created for all adapters. A problem there would also not crash the js-controller itself. If you need less RAM usage you can manually change that and configure the instances to run on group 0 (=inside js-controller).
Feature status: Technology preview (since 2.0.0)
To enable compact mode for a js-controller instance, you can use the new "compact" CLI commands, or you can manually change the iobroker.json
configuration file
{
...
"system": {
...
"compact":true
}
...
}
and restart the js-controller.
Feature status: Technology preview (since 2.0.0)
To be able to handle the risk of crashed controller processes affecting the whole system it is possible to assign the adapter instances to different compact groups. Each group will be run in their own process, only group 0 is handled directly by the main js-controller process.
Using several compact groups you can, by using a bit more memory, lower the risk of a crashing js-controller main process.
Compact groups can be configured for the respective instances using the compact CLI commands (see ìobroker compact commands on https://www.iobroker.net/#de/documentation/config/cli.md).
https://forum.iobroker.net/topic/18338/experimentell-js-controller-compact-mode
For testing, set up your js-controller to use compact mode and change the io-package.json
and javascript files accordingly. Do not forget to iobroker upload adaptername
after changing io-package.json
.
Please check that your adapter starts and runs as expected also when compact mode is used.
For adapters running in compact mode, special care must be taken to clean up used resources without throwing errors. You need to make sure that all initialized connections, timers and intervals are closed and stopped in the unload
handler.
Feature status: stable, since js-controller 3.0
The js-controller checks the available RAM of the system before starting a new adapter process. If the available RAM is below 50/100 MB by default an error/warn is logged. The limits can be configured in iobroker.json
"system": {
"memLimitWarn": 100,
"memLimitWarnComment": "If the available RAM is below this threshold on adapter start, a warning will be logged.",
"memLimitError": 50,
"memLimitErrorComment": "If the available RAM is below this threshold on adapter start, an error will be logged."
}
...
Later versions of js-controller might prevent start of a new adapter process if system resources are too low!
Feature status: stable
For debugging reasons sometimes it is necessary to start an adapter instance via the command line to get more detailed logging.
To do so, manually execute the adapter's main javascript file, which is usually named main.js
or <adaptername>.js
(where "adaptername" is the name of the adapter):
node node_modules/iobroker.adaptername/main.js --force --logs
All log output will now be printed to the console.
Feature status: stable
When local interfaces are required or the host system is reaching its resource limits, the ioBroker system can be distributed to additional hosts. All hosts in a multihost environment are connected to the same states and objects databases and are thus synchronized with each other.
When the states and/or objects databases are provided by a js-controller process on one host, this "master" host needs to be configured so the databases are available on the local network. To do so, enter 0.0.0.0 as the address in iobroker setup custom
instead of 127.0.0.1.
All other hosts are configured to connect to this master host.
For detailed setup instructions see https://www.iobroker.net/docu/index-24.htm?page_id=3068&lang=de
Feature status: Technology preview (since 3.3.0)
Starting from js-controller 3.3.0 you can define the common.tier
attribute in the io-package.json.
Lower TIERS will start before higher TIERS. Currently, 3 TIER levels are supported.
Note, that the admin adapter as the central control platform will always be started first.
Logic and scripting engines, which should be able to act as fast as possible to work with states delivered by higher TIER adapters.
Adapters which deliver data from external APIs, which are important and can change at any time
Adapters which are not time critical like Visualization, Backup adapters and adapters whose information do
not necessarily need to be up-to-date. These are often schedule
adapters, whose information is always a bit delayed.
Feature status: stable (since 2.0.0)
Feature Flag for detection: ALIAS, ALIAS_SEPARATE_READ_WRITE_ID
The Alias Feature allows defining one object/state to be the "alias" of another object/state.
All Aliases will be created in the Object namespace alias.0
Effectively an alias
object will mirror the state value of the target object.
If allowed, both states can be changed and are synced automatically by the ioBroker core system.
Also, both states can be used to subscribe in scripts and should behave exactly identical.
Additionally, to defining the target ID the alias object can also define "read and write functions" to do easy value conversions, so e.g. the target state could contain a power measurement value in Wh (because an adapter delivers the value that way) and the alias could use the same value calculated as kWh.
Some devices have separate states for semantically one state. One to read the current status from and one to write to, to control the device. You can combine these states into one alias by using a separate alias id to write to and another to read from.
As of now (js-controller 2.0.0 release) there are no front-ends to configure alias.
To create an alias object simple create a new object with a own name in the alias.0
namespace and add the alias definition in the common section (here for an alias with the id "alias.0.aliasName"
):
{
_id: "alias.0.aliasName",
common: {
name: 'Test AliasC',
type: 'number',
role: 'state',
min: -10,
max: 10,
alias: {
id: 'state.id.of.target',
read: 'val * 10 + 1',
write: '(val - 1) / 10'
}
},
native: {},
type: 'state'
}
or using different read and write ids (supported starting js-controller 3.0, check using feature flag ALIAS_SEPARATE_READ_WRITE_ID):
{
_id: "alias.0.aliasName",
common: {
name: 'Test AliasC',
type: 'number',
role: 'state',
min: -10,
max: 10,
alias: {
id: {
read: 'state.id.to.read.from',
write: 'state.id.to.write.to'
}
read: 'val * 10 + 1',
write: '(val - 1) / 10'
}
},
native: {},
type: 'state'
}
The following fields are allowed in the alias structure:
alias.id
contains the ID of the target object/state to mirror OR (since js-controller 3.0) represents an object with the following two properties:alias.id.write
contains the ID of the object which will be set when alias is writtenalias.id.read
contains the ID of the object which will be mirrored to the alias object/state
alias.read
can optionally contain a read script (will be evaluated) to calculate the alias value when the target state changesalias.write
can optionally contain a write script (will be evaluated) to calculate the target value if the alias value is changed
Note, that alias states will be automatically scaled if the following conditions match:
- target and source state are of type
number
- either the alias state or (not both) the source state are of unit
%
- no
read
orwrite
function is defined - the state which is not of unit
%
has a validmin
andmax
property
To set the alias properties without a JavaScript or in adapter code you can also use the cli commands like:
iobroker object set alias.0.aliasName common.alias.id=state.id.of.target
iobroker object set alias.0.aliasName common.alias.read="read-func"
iobroker object set alias.0.aliasName common.alias.write="write-func"
Additional information about aliases could be found here.
ioBroker is storing three different type of data:
- objects contain the metadata, descriptions and configuration values for all objects and states stored by ioBroker. Objects are created initially and sometimes updated, but usually not changed very frequently
- files are all JSON, image and other files that are accessible for all ioBroker adapters. A
meta.user
object needs to exist for the adapter or instance to define allowed root directories. As example see sayit adapterio-package
. - states contain the real data from sensors, devices and objects which are updated frequently
By default, the js-controller process is offering in-memory DBs at ports 9000 (for states) and 9001 (for objects/file). All adapter processes and js-controller processes from other hosts connect to these databases to read and store data.
The in-memory DBs for states and objects use JSON files to store the data. The files are stored after changes every 30 seconds and are backed up automatically. The files are stored in iobroker-data directory, the backups in a sub folder.
The in-memory DBs work well for up to 10000 objects and normal state update frequencies. When your system has more objects and states or its states are updated very often, it is a better idea to use Redis as the database engine. A good indicator for this if the js-controller process is using a lot of CPU and/or the system feels slow.
js-controller 1.x was using socket.io as the communication protocol between the adapters and the in-memory DBs. Starting with js-controller 2.0, the communication protocol was changed to be a lightweight Redis protocol. This simplifies the logic and should increase performance.
For the objects and states databases special additional logging of the redis protocol messages can be activated in iobroker.json
"objects": {
...
"enhancedLogging": false
}
When not configured differently the file databases are persisted every 15s (15000ms) after data are changed. The interval in ms can be changed by configuration in iobroker.json starting js-controller 3.0. Note: If you do that be aware that you may lose data when the js-controller crashes unexpectedly!
"objects": {
...
"writeFileInterval": 60000
}
Redis is a well known industrial grade in-memory database optimized for speed and stability. It performs better than the ioBroker In-Memory database which is written in JavaScript.
- Linux from here: https://redis.io/download
- Windows from here: https://github.com/MSOpenTech/redis/releases
e.g. for Linux: https://www.digitalocean.com/community/tutorials/how-to-install-and-secure-redis-on-ubuntu-18-04
ioBroker requires the "Locale" for the redis-server process to be set to "LANG=C" instead of other locales in order to get correct sorted results when Objects are stored in Redis.
On Linux ideally set the LC_ALL environment variable for the redis-server process correctly. For more informations to see if changes are meeded and how to do them see https://forum.iobroker.net/topic/52976/wichtiger-hinweis-f%C3%BCr-redis-installationen (German right now).
Ideally the Redis server should be installed on the same host as the js-controller process because as soon as Redis is configured to be used the ioBroker installation will not work without it.
If you plan to install Redis on a different host then the js-controller or use a multi-host environment (see below), you must allow connections to redis from any address (the default only accepts connections from 127.0.0.1).
To do that edit the file /etc/redis/redis.conf
(sudo nano /etc/redis/redis.conf
) and replace bind 127.0.0.1
with bind 0.0.0.0
.
Don't forget to restart redis after that. (sudo systemctl restart redis-server
)
If you have multiple hosts, you can install Redis to all of them and configure the other hosts to be slaves of the Master host. With this all data is available on all hosts, so even if one host crashes completely, you still have the database content from the other hosts.
More details can be found at https://redis.io/topics/replication#configuration and https://redis.io/commands/replicaof
Redis slaves will be not writable by default.
In case of a crash of the master you can reconfigure one of the slaves to be the new master and it will use the current content. After reconfiguring all slaves to sync with the new Master the redis database is functional again.
After reconfiguring Redis you also need to update all ioBroker states/objects DB settings to connect to the new Redis Master host.
By default, Redis is a pure in-memory Database which means that it has no content when it starts. In the default configuration, the content of the redis DB is stored on disk after a certain amount of changed keys.
Depending on how many changes your system is doing it will update the data on disk roughly every 5 minutes by default. Please consider this if your system runs from an SD card (like Raspberry Pi).
If you are not working on a SD card and want to have real up-to-date data on disk you can use the second persistence method called AOF. Else the latest dumped data are used, which could be some minutes old.
Please see https://redis.io/topics/persistence for details, differences and configuration information for both persistence options.
Feature status: stable
There is a possibility to use Redis as states database. It is reasonable to do that for big installations or for systems with performance problems. It is possible to switch anytime between Redis and in-memory Javascript DB.
Note for js-controller <2.0: After changing to Redis, all states must be updated by the adapters again (the previous values will be lost). Please especially note this for the state values from own JavaScript states! Objects and configuration are not affected.
To switch to Redis, execute the following on the console:
iobroker stop
iobroker setup custom
And then enter redis
as the states DB type (line 4):
Type of objects DB [file, redis], default [file]:
Host of objects DB(file), default[127.0.0.1]:
Port of objects DB(file), default[9001]:
Type of states DB [file, redis], default [file]: redis
Host of states DB (redis), default[127.0.0.1]:
Port of states DB (redis), default[6379]:
Data directory (file), default[../../../iobroker-data/]:
Host name of this machine [FastPC]:
creating conf/iobroker.json
Now ioBroker can be started.
If it does not start, please check the log at log/iobroker.*.log
in the ioBroker directory. Please also check the redis is running (use e.g. redis-cli
) and that the firewall set up correctly.
To switch back to file based states write the same commands again, just instead of redis in fourth line write nothing and press ENTER.
Feature status: New in 2.0.0
Starting with js-controller 2.0.0, objects and files can also be stored in Redis. Since Redis holds all data in the RAM, this setup uses much more RAM because uploaded files and image assets are also stored in Redis. Please think carefully about this step and make sure your system has enough RAM available!
The setup is comparable to the setup for states in Redis by using iobroker setup custom
, but enter redis as type of the objects' database. You can use the same redis server for states and objects/files database.
Feature status: New in 2.0.0
Redis Sentinel is an industry standard to achieve a highly available redis database. It is based on a Redis master-slave setup with at least three nodes. Additional so-called sentinel processes monitor all redis instances in the master-slave setup.
If the master is going offline, the sentinel processes react and coordinate to select a new master. After this is done, the master-slave cluster is reconfigured and the new master is taking over.
More details about the Redis sentinel can be found in the official documentation at https://redis.io/topics/sentinel .
ioBroker allows to use a Redis Sentinel system. For this you use iobroker custom
like above, but provide a comma separated list of the sentinel hosts. For the sentinel ports you can either enter a comma separated list with the same number of entries, or a single one which is then used for all hosts.
With such a setup, ioBroker will connect to one of these sentinel processes to get the current Master Redis and then connect to it. When the connection to the Master is disconnected, all data updates are cached and transmitted as soon as a connection to the new master has been established.
Feature status: Stable
... CLI ... Files vs PEM content ... TODO
... see web ... letsencrypt.js ... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
... TODO
Feature status: Stable
TODO: Link to Adapter Development docs
Feature status: Stable, since js-controller 3.0
Since js-controller 3.0 the adapter developer can define an array or field names in io-package.json as encryptedNative to define which fields should be automatically encrypted before being stored by Admin and decrypted when the adapter process starts. The values are not decrypted when the object itself is read!
With this change and the Admin support for this soon the adapter developer do not need to struggle around with encryption or decryption of adapter values and can simply configure this.
To preserve backward compatibility you can check for the feature flag ADAPTER_AUTO_DECRYPT_NATIVE or add a global Admin dependency to the respective Admin (>=4.0.10) version.
Feature status: Stable, since js-controller 2.0
Normally all objects can be read by any adapter using getObject or getForeignObject. To make sure sensible adapter configuration values are protected from that free reading they can be secured.
If an array with field names from native is defined in io-package.json as common.protectedNative the ioBroker system will sort these fields out when the object is read. Only the adapter itself is allowed to read the full object.
It is best practice adding the field names of encrypted fields to the protectedNative array too to make sure the fields stay protected (even if encrypted). Only let other adapters read your encrypted values if there is a need to (e.g. adapter interoperability)
Feature status: Stable
Dependencies are defined in array and can contain an adapter name of an object.
When using the object style you can define a semver version range for this adapter:
"dependencies": [
{
"js-controller": ">=2.0.0"
}
],
If the version do not matter and just the adapter itself needs to be present you can also use:
"dependencies": [
"web"
],
There are two types of adapter dependencies that can be defined in io-package.json and will be checked on installation and adapter start.
common.dependencies for Same Host dependencies
With common.dependencies
in io-package.json you can define if an adapter needs to be present on the same host and optionally in which version.
This is mainly used to define the needed "js-controller" version for yor adapter and can also be relevant e.g. for web extension adapters (adapters that can be plugged in into the web adapter, so the code needs to be on the same host).
common.globalDependencies for dependencies on any Host With common.globalDependencies in io-package.json and starting with js-controller 3.0 you can define a global dependency that will be checked over all hosts. Irrelevant where on the system the referenced adapter is installed it needs to match the version and at least one instance needs to exist. This can mainly be used for more loose dependencies where adapters are split over multiple hosts but still work together, e.g. Admin.
Feature status: Stable
The js-controller allows adapters to subscribe to log messages from other adapters and react on them. For details see https://github.com/ioBroker/ioBroker.js-controller/blob/master/doc/LOGGING.md
Feature status: Stable since js-controller 2.0.0
Since js-controller 2.0 there exists a dedicated method to detect if certain features exists for an adapter.
The preferred way to use it (also because of backward compatibility reasons) is:
if (adapter.supportsFeature && adapter.supportsFeature('NAME')) {
// ...
}
The following features can be checked using this method:
- ALIAS: checks if the Alias feature is existing (since
js-controller
2.0) - ALIAS_SEPARATE_READ_WRITE_ID: allows specifying separate ids for read and write (since
js-controller
3.0) - ADAPTER_GETPORT_BIND: the adapter.getPort method allows an optional second parameter to bind the port only on a special network interface (since
js-controller
2.0) - ADAPTER_SET_OBJECT_SETS_DEFAULT_VALUE: adapter.setObject(*) methods now sets the default value (def) after the object was created (since
js-controller
2.0) - ADAPTER_DEL_OBJECT_RECURSIVE: adapter.delObjects supports
options.recursive
flag to delete whole object structures (since js-controller 2.2) - ADAPTER_AUTO_DECRYPT_NATIVE: The Controller supports auto decryption of encrypted native properties (since js-controller 3.0)
- PLUGINS: Plugins are supported by this js-controller and adapters, see section below for more details (since js-controller 3.0)
- CONTROLLER_NPM_AUTO_REBUILD: Automatic rebuild when node version mismatch is detected (since js-controller 3.0)
- CONTROLLER_READWRITE_BASE_SETTINGS: Allow read and write of js-controller base settings file (iobroker.json) via host messages (since js-controller 3.0)
- CONTROLLER_MULTI_REPO: indicates that controller supports multiple repository sources, which will be combined in one (since js-controller 4.0)
- CONTROLLER_LICENSE_MANAGER: js-controller can read licenses from iobroker.net (since js-controller 4.0)
- DEL_INSTANCE_CUSTOM: indicates that controller is able to delete all custom attributes of an adapter and instance if it is deleted via
--custom
flag (since js-controller 4.0)
To check if certain adapter methods itself are existing please simply check for their existence like
if (adapter.getObjectView) {
// ...
}
or
if (typeof adapter.getObjectView === 'function') {
// ...
}
Feature status: Stable since js-controller 3.0.0
Starting with js-controller 3.0 a flexible plugin system is available to the js-controller and also to adapters.
Plugins are custom modules that can be configured in io-package.json in a new "plugins" section and provide central functionality on the level of the adapter or js-controller process. The modules are automatically loaded and configured. Depending on the plugin they can be enabled or disabled by setting system.host
or system.adapter
states.
More details about plugins and their development can be found at the Plugin-Base repository. A simple implementation can be found at the Sentry-Plugin
New Plugins should always be developed, reviewed and published by ioBroker Core developers! Contact @Apollon77 or @GermanBluefox for this.
Since js-controller 3.0 the sentry plugin is integrated and activated by default in js-controller. See information above.
There is a special maintenance mode. It is used by some special adapters, that will clean the objects and states from invalid entries. Invalid entries could be:
- has invalid ID (e.g. null, empty or with prohibited chars, very long IDs over 2000 chars),
- has empty object or with no object type.
- states, that have no according entry in object DB
To make possible to get such an entries, the maintenance mode was implemented.
To make a call in maintenance mode, you must provide options
object with at least following attributes:
{
user: 'system.user.admin',
maintenance: true,
}
Following adapter methods support maintenance mode:
- adapter.getForeignState
- adapter.getForeignObject
- adapter.setObjectWithDefaultValue
- adapter.setForeignObject
- adapter.setObjectNotExists
- adapter.delForeignObject
- adapter.getForeignState
- adapter.delForeignState
- adapter.setBinaryState
- adapter.getBinaryState
- adapter.delBinaryState
*** Do not use this mode for any other purposes except sanitizing/cleaning/repairing of existing DBs (Object and States)***
The goal is to release an update for the js-controller roughly all 6 months (April/September). The main reasons for this are shorter iterations and fewer changes that can be problematic for the users (and getting fast feedback) and also trying to stay up-to-date with the dependencies.
For the dependencies we will use depend-a-bot. In general the goal is still to support a certain range of node.js LTS versions. Currently, js-controller 3.0 will start with nodes 10.x up to 12/14.x. If dependency updates would break that and would require a major-release, this will be discussed and decided on core developer level BEFORE merging such a dependency change!
For the planned changes we use a backlog approach. This means that out of the existing issues for the project the core developers select issues to put into a prioritized backlog in the project view. Other users also can propose tickets. All merged PRs (also when unplanned/not prioritized before) are included as finished tickets in the project (so project is assigned to them manually on merge). When a ticket is contained in the backlog this does not mean that it will be done in the next version! But it helps if developers have some time to see what’s considered important. The current project will always get the name „Next Release“. All older projects will get the respective release version number to know the history.
Roughly at the end of each first/third quarter (so 31.3. and 30.9.) we will finalize the next release version, update change logs. A version branch for this version is created that will allow hotfixes. 1-2 weeks before that cut-off date no new feature PRs should be added. Changes are flagged as [Bugfix], [Feature] or [Breaking Change] in changelog (ideally also in PRs) and the version increase is depending on the type of the changes.
After this we will have a testing phase for this version. Once tests ended successfully it will be published to „latest“ repository to get feedback from community. After this it goes too stable. Depending on the problems, bugs and feedback the goal is to release the stable version roughly 1 - 1.5 month after cut-off date from the version.
All changes should be added via PRs that are reviewed and merged by the core developers. PRs are flagged as [Bugfix], [Feature] or [Breaking Change].
It is also allowed to introduce unfinished new features, as soon as they do not break the system. We will also start to introduce „testing quality features“ that only may be configured manually in JSON files or via CLI. They are then flagged as „Technology Preview“. This means we will not delay a new js-controller version because a new feature is not possible to configure via admin. The feature list and details in js-controller README needs to be updated as soon as the feature is ready in general (including "Technology preview"). Unfinished features are not included in the README even if existing partly in the code.
This new process and rules are introduced with js-controller 2.0 and updated to a 6 months cycle with js-controller 3.0.
The MIT License (MIT)
Copyright (c) 2014-2022 bluefox [email protected],
Copyright (c) 2014 hobbyquaker