This concerns Tau Argus version 4.1.7, windows version, with tabular input.
The text was updated successfully, but these errors were encountered:
ppdewolf
changed the title
TA, status of the cells (confidentiality) is lost when using the option enforce protection
TA, status of the cells (confidentiality) is lost when using the option enforce additivity
Mar 26, 2021
Since making the table additive will change some cell values, it is not obvious how the sensitivity rule is influenced: only the cell values is adjusted, not the underlying contributions. That's the reason why the statusses are not maintained when making a table additive.
However, I assume that the tabular input has the statusses you want. Then a workaround would be to put these statusses in a "apriori file" (.hst) and import them after the table is made additive.