Notifications
You must be signed in to change notification settings - Fork 158
Tips And Tricks
NOTE: As of the 3.0 final release, the registry settings are no longer recognized. Instead, use settings in the
.runsettings
file.
Certain NUnit Test Adapter settings are configurable using a .runsettings file. The following options are available:
Key | Type | Options | Default |
---|---|---|---|
InternalTraceLevel | string | Off, Error, Warning, Info, Verbose, Debug | Nothing => Off |
NumberOfTestWorkers | int | nr of workers | -1 |
ShadowCopyFiles | bool | True, False | False |
Verbosity](#Verbosity) | int | -1, 0 -5 . -1 means quiet mode | 0 |
UseVsKeepEngineRunning | bool | True, False | False |
BasePath | string | path | ? |
PrivateBinPath | string | directory1;directory2;etc | ? |
RandomSeed int | seed integer | random | |
DefaultTimeout | int | timeout in mS, 0 means infinite | 0 |
DefaultTestNamePattern | string | Pattern for display name | {m}{a} |
DomainUsage | string | None, Single, Multiple | Single |
WorkDirectory | string | specify directory | Test assembly location |
DumpXmlTestDiscovery | bool | Enable dumping of NUnit discovery response xml | false |
DumpXmlTestResults | bool | Enable dumping of NUnit execution response xml | false |
https://github.com/nunit/nunit3-vs-adapter/blob/master/src/NUnitTestAdapter/AdapterSettings.cs#L143
Our WorkDirectory is the place where output files are intended to be saved for the run, whether created by NUnit or by the user, who can access the work directory using TestContext. It's different from TestDirectory, which is the directory containing the test assembly. For a run with multiple assemblies, there could be multiple TestDirectories, but only one WorkDirectory. User sets work directory to tell NUnit where to put stuff like the XML or any text output. User may also access it in the code and save other things there. Think of it as the directory for saving stuff.
This setting is a diagnostic setting forwarded to NUnit, and not used by the adapter itself. For further information see the NUnit Tracelevel documentation
This setting is sent to NUnit to determine how parallelization should be performed.
This setting is sent to NUnit to enable/disable shadow-copying.
This controls the outputs from the adapter to the Visual Studio Output/Tests window. A higher number includes the information from the lower numbers. It has the following actual levels:
-1 : Quiet mode. Only shows errors and warnings.
0 : Default, normal information verbosity
1-3: Some more information from setting are output (in particular regarding parallelization)
4: Outputs the values from the runsettings it has discovered.
5: Outputs all debug statements in the adapter
This setting is used by the adapter to signal to the VSTest.Execution engine to keep running after the tests have finished running. This can speed up execution of subsequent test runs, as the execution engine already is loaded, but running the risks of either holding onto test assemblies and having some tests not properly cleaned out. The settings is the same as using the Visual Studio Test/Test Settings/Keep Test Execution Engine running.
These settings are used to dump the output from NUnit, as it is received by the adapter, before any processing in the adapter is done, to disk. It is part of the diagnostics tools for the adapter. You can find the files under your current outputfolder, in a subfolder named Dump. (Note: This is not the same as the TestResults folder, this data is not testresults, but diagnostics dumps)
Some further information on directories (From comment on issue 575 by Charlie )
NUnit also supports TestContext.TestDirectory, which is the directory where the current test assembly is located. Note that if you have several test assemblies in different directories, the value will be different when each one of them accesses it. Note also that there is no way you can set the TestDirectory because it's always where the assembly is located.
The BasePath is a .NET thing. It's the base directory where assemblies are searched for. You can also have subdirectories listed in the PrivateBinPath. NUnit take scare of all this automatically now, so the old console options are no longer supported. For finding things you want to read at runtime, the TestDirectory and the BasePath will usually be the same thing.
Certain settings in the registry affect how the adapter runs. All these settings are added by using RegEdit under the key HKCU\Software\nunit.org\VSAdapter.
By default NUnit no longer uses shadowcopy. If this causes an issue for you shadowcopy can be enabled by setting the DWORD value UseShadowCopy to 1.
By default the NUnit adapter will "Kill" the Visual Studio Test Execution engine after each run. Visual Studio 2013 and later has a new setting under its top menu, Test | Test Settings | Keep Test Execution Engine Running. The adapter normally ignores this setting.
In some cases it can be useful to have the engine running, e.g. during debugging of the adapter itself. You can then set the adapter to follow the VS setting by setting the DWORD value UseVsKeepEngineRunning to 1.
Normally the adapter reports exceptions using a short format, consisting of the message only. You can change it to report a verbose format that includes the stack trace, by setting a the DWORD value Verbosity to 1.
Copyright (c) 2018 The NUnit Project - Licensed under CC BY-NC-SA 4.0