You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I was processing the ENDF/B-VIII.0 libraries into ACE format following the procedures suggested in "Release of ENDF/B-VIII.0-Based ACE Data Files" (LA-UR-18-24034), I'm using NJOY2016.35 and I noticed something strange with the Na-22 and Ne-22.
In the report it is mentioned that Na-22 shows negative cross sections in the probability tables, therefore the PURR module was not considered. I noticed the same behaviour and I tried to eliminate the PURR module from my input. However, by testing a temperature of 293.6 K, keeping the PURR module in the NJOY input for Na-22 I retrieve the exact 11022.800nc ACE file from the Lib80x repository.
On the contrary, if I process the Ne-22 without the PURR module I obtain the exact 10022.800nc.
The same happens for all the other temperatures.
Is it possible that the PURR module was erroneously removed from the input decks of Ne-22 instead of Na-22?
I share my input decks and my ACE files as references.
Thanks! IssueNa22Ne22.zip
The text was updated successfully, but these errors were encountered:
Hello!
I was processing the ENDF/B-VIII.0 libraries into ACE format following the procedures suggested in "Release of ENDF/B-VIII.0-Based ACE Data Files" (LA-UR-18-24034), I'm using NJOY2016.35 and I noticed something strange with the Na-22 and Ne-22.
In the report it is mentioned that Na-22 shows negative cross sections in the probability tables, therefore the PURR module was not considered. I noticed the same behaviour and I tried to eliminate the PURR module from my input. However, by testing a temperature of 293.6 K, keeping the PURR module in the NJOY input for Na-22 I retrieve the exact 11022.800nc ACE file from the Lib80x repository.
On the contrary, if I process the Ne-22 without the PURR module I obtain the exact 10022.800nc.
The same happens for all the other temperatures.
Is it possible that the PURR module was erroneously removed from the input decks of Ne-22 instead of Na-22?
I share my input decks and my ACE files as references.
Thanks!
IssueNa22Ne22.zip
The text was updated successfully, but these errors were encountered: